How to Repair the ER05 or ER06 Error on the Breville/Sage Touch BES880

Repair Time: 15 minutes


Click here to order this part

 

Step-by-Step:

Step 1: Unplug the machine and remove the water tank, bean hopper and tray.

Step 2: Remove the five phillips screws underneath to release the two panels:

Step 3 - Remove the four screws holding the sensor board in:

Step 4 - This will allow the sensor cover to be removed:

Step 5 - Take off the rubber boot and spring holding the sensor assembly in place:

Step 6 - Unclip the sensor board cable to release:


Step 7 - Remove the broken sensor wire and thread the new one in place - use a small screwdriver to help it along:

Step 7 - Ensure the three jug sensor pads line up correctly, when you fit the board back in place - otherwise you will get jug placement errors:

Make sure you don't twist the new sensor wires, otherwise you will get ER07 or ER08 errors:

And that's it. Just make sure you hold the triangular piece in place while you put the screws back in:

Then place the spring and rubber boot back on, along with the three covers to finish the repair:

 

 

> ⚠️ Warning: DIY repairs carry risk. Do not attempt if unsure. See full [disclaimer].